Naturelite Technologies Co.,Limited
|
Gold Index: 10079
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
SCR Dimming LED Panel Light ENEC EN61347-1,EN61347-2-13 independent,EN62384 approved
Description:
SCR Dimming LED Panel lamp
(1)AC phase-cut dimming.
(2) Work with leading edge and trailing edge TRIAC dimmers.
(3) Built-in active PFC function SCR Dimming LED panel light.
(4) Constant current design.
(5) Protections: Short circuit/Over temperature.
(6) Cooling by free air convection.
(7) Fully isolated plastic case.
(8) IP 30 design.
(9) Class power unit, no FG.
(10) Suitable for indoor LED lighting applications.
(11) 100% full load burn-in test.
(12) Low cost.
(13) High reliability.
(14) SCR Dimmable Panel light 3 years warranty.
SILICON CONTROLLED RECTIFIER PANEL LIGHTS DESCRIPTION
SCR Dimming LED panel light a kind of economical intelligent control lamp compared with other dimmable led panel light, you can adjust the brightness through the touch screen.
Applications:
Sitting room;
Bedroom;
dining room;
corridor;
hotel,etc.
Suggestion: the installation height of droplight, the lowest point shall be not less than 2.2 meters off the ground.
Features:
Product Name |
SCR Dimming LED Panel Light |
Power Factor(Typ.) |
PF>0.9/230VAC,PF>0.9/277VAC at full load |
Setup Time |
500ms/230VAC at full load |
Efficiency(Typ.) |
85% |
Voltage Range |
180~295VAC |
Inrush Current(Typ.) |
COLD START 13A(twidth=50μs measured at 50% lpeak) at 230VAC |
Frequency Range |
47~63Hz |
Safety Standards |
ENEC EN61347-1,EN61347-2-13 independent,EN62384 approved |
Specifications:
Model |
CLP-NSCR-6060 |
Setup Time |
500ms / 230VAC at full load |
Voltage Range |
180~295VAC |
Frequency Range |
47~63Hz |
Power Factor(Typ.) |
PF>0.9/230VAC,PF>0.9/277VAC at full load |
Total harmonic distortion |
THD<20% |
Efficiency(Typ.) |
85% |
Input Voltage |
<48V |
Inrush Current(Typ.) |
COLD START 13A(width=50μs measured at 50% peak) at 230VAC |
Leakage Current |
<0.5mA /240VAC |
Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed |
Over Temperature |
Shut down o/p voltage, auto-recovery |
Working Temp |
-30~+45(Refer to "Derating Curve”) |
Working Humidity |
20~95%RH,non-condensing |
Storage Temp., Humidity |
-40~+80,-10~+95RH |
Temp. Coefficient |
±0.03%/(0~50) |
Safety Standards |
ENEC EN61347-1,EN61347-2-13 independent,EN62384 approved |
Withstand Voltage |
I/P-O/P:3.75KVAC |
EMC Emission |
Compliance to EN55015,EN61000-3-2 Class C; EN61000-3-3 |
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11,EN61547 |
Naturelite Technologies Co.,Limited [China (Mainland)]
Business Type:Manufacturer
City: Shenzhen
Province/State: Guangdong
Country/Region: China (Mainland)